Check the wiring diagram on the cover of the electrical box of your outdoor machine and the color of the wires on the capacitor terminals and binding post terminals.
Each different brand model may have a different color for the compre ssor power supply wire. Generally, there are letters marked on the compre ssor cover.
R (running end): Connect one end of the starting capacitor and the wiring Column neutral terminal N is connected in parallel
S (starting end): connected to the other end of the starting capacitor
C (common end): connected to the compre ssor power input How to connect the circuit of Haier air conditioner KFR-26GW
Look at the wiring diagram. If you cannot understand the diagram, you can only wire it according to the following method:
You can use a multimeter to measure the coil resistance and make connections based on the resistance.
The two ends with the largest resistance are connected to the capacitor, and the two ends with the smallest resistance are connected to the power supply (L) and N.
The specific wiring is as follows: